IGEM/UP11/Edition 2, Gas installations for educational establishments

IGEM/UP11/Edition 2, Gas installations for educational establishments

The Institute of Gas Engineers and Managers (IGEM) document UP11 Edition 2, Gas installations for educational establishments.

This is a comprehensive document that, in our opinion, has paid much consideration to common sense though some of the descriptions and terms used are outdated. Below are some relevant extracts. Please call or email for more information should you require it.

Laboratory gas control

The document states under 6.2.4.1 that, “Where an AIV (gas solenoid valve) is required the system shall include a downstream integrity check before the valve can be reopened.”
“Downstream integrity check” means gas pressure proving system.

The term “Where required” is explained in 6.2.3 where it says that “where it is not practicable to install a manual quarter turn valve in a readily accessible position, or where it is required to interlock the gas supply with other safety systems such as air flow, fire or gas detection an automatic means of isolation shall be installed.”

The term “automatic means of isolation” is explained in 6.2.4
where it describes the term as meaning a gas pressure proving system.
In relation to the use of gas pressure proving the IGEM documents UP1A Edition 2 and UP2 Edition 2 give more advice on the utilisation of proving for safety.

Food Technology

Section 11.2.4. states that “mechanical ventilation or extract systems shall be interlocked”.

Also 11.2.4 goes on to say:
Note. Must be read in conjunction with 11.2. 5 and accompanying note. “Where the ventilation requirements for new installations cannot be met, CO2 monitoring shall be fitted. It shall provide an alarm condition at not more than 2,800 ppm to warn the teaching staff to increase ventilation and an automatic shut down of the gas supply at 5,000 ppm.”

Section 11.2.5 is clear in stating that:
“Means shall be provided to monitor the correct provision of air supplies, for example by airflow monitoring by air flow switches or by fan power monitoring. Failure shall lead to the shut down of the gas supply to the cookers.”

“Air supplies” also means extract and “fan power monitoring” means current monitoring in modern terms. As part of the interlock control a gas pressure proving system should be incorporated. For further information see Medem talking point entitled Individual laboratory control

Gas detection & Carbon Monoxide monitoring in classrooms

6.2.5.5 and 6.2.5.6 in essence requires that where a boiler room is connected to a teaching area then CO monitoring should also be installed in the occupied area. Consideration should also be given to installing combustible gas detectors within the same teaching area.

If you require any additional information on our systems to help meet these design standards or wish to discuss the standards further please don't hesitate to contact us.
twitterlogo @MedemUkLtd

enquiries@medem.co.uk

Building Bulletin 80, Science accomodation in Secondary schools.

Building Bulletin 80, Science accomodation in Secondary schools.

The BB80 document offers guidance relating to the new design and refurbishment of science accommodation.

more >>

Building Bulletin 101, ventilation of school buidlings

Building Bulletin 101, ventilation of school buidlings

Building Bulletin 101 is a 2nd tier regulatory document to the Building Regulations part F.It covers ventilation in education buildings

more >>

Individual laboratory control?

Individual laboratory control?

There are three main areas of gas control in education buildings:

Boiler room
Production Kitchen

more >>

SEC-L

SEC-L

The SEC-L, a multi-function solution designed for the laboratory

Gas pressure proving
Gas detection
Electrical and Water isolation
Demand controlled ventilation

more >>

SEC-K - kitchen interlock

SEC-K - kitchen interlock

The SEC-K - kitchen interlock gas system. Ventilation interlock and gas proving system with multiple features available where and when required

more >>

GPPS-evo

GPPS-evo

GPPS-evo, combines and supersedes the GPPS-L & L-CO2 panels

more >>

SEC-Elite

SEC-Elite

The SEC-Elite is a gas proving system capable of pressure proving up to 4 gas lines from a single panel with individual control.

more >>