IGEM/UP/1A/ Edition 2, Strength testing, tightness testing......

IGEM/UP/1A/ Edition 2, Strength testing, tightness testing......

IGEM/UP/1A/Edition 2, Strength testing, tightness testing and direct purging of small, low pressure industrial and commercial Natural Gas installations.

Section 2: Scope 2.4 states that the document procedures apply in relation to the following (amongst others);
“Where there has been a complete loss of pressure for any reason, note, The closure of a valve, for example the ECV, can result in the complete loss of pressure which necessitates tightness testing and purging before resumption of supply”

An explanation of the above in relation to gas pressure proving. The first referring to the words “can result in the complete loss of pressure”. When a solenoid or other type of ECV closes for whatever reason if a downstream boiler, appliance or Bunsen burner is switched on then the gas pressure will be lost.
This is likely to happen particularly where flame safety devices are fitted.

Further reasons for the use of gas pressure proving systems can be found in IGEM UP2/ Edition 2

If you require any additional information on our systems to help meet these design standards or wish to discuss the standards further please don't hesitate to contact us.
twitterlogo @MedemUkLtd

enquiries@medem.co.uk

Building Bulletin 100, Design for fire safety in schools

Building Bulletin 100, Design for fire safety in schools

Building Bulletin 100, Design for safety in schools

This is a very comprehensive document so here are just a couple of extracts that ....

more >>

IGEM/UP2/Edition 2

IGEM/UP2/Edition 2

Within IGEM/UP/2 Edition 2 it highlights the potential risks surronding the control of gas solenoid valves (AIV's) and automatic restarting.

more >>

Differential pressure proving?

Differential pressure proving?

Why choose Medem differential pressure proving?

The differential gas pressure proving method as developed and patented by Medem operates by *measuring* the pressure deferentially across the inlet and....

more >>

VGPS-evo - kitchen interlock gas system

VGPS-evo - kitchen interlock gas system

The VGPS-evo offers a complete single panel package patented by Medem UK

VGPS-evo, a gas pressure proving system with ventilation interlock and CO2 monitoring designed for commercial kitchens.....

more >>