Why fit gas pressure proving in a commercial kitchen

Why fit gas pressure proving in a commercial kitchen

We are still on occasion asked to supply a system that performs ventilation interlock alone, without gas pressure proving. Although we do have such a system, it was one of our first in fact, we don't consider it best practice and would always recommend a combined gas pressure proving and ventilation interlock system

Why?

Consider the following…

During normal usage the ventilation goes off regardless of reason, the ventilation interlock system will close the gas solenoid valve, isolating the incoming gas supply just as it should.
Any kitchen appliances using gas at this time would continue to do so until all the remaining gas (between the valve and appliances) is consumed at which point a flame failure device (if fitted) would isolate the appliance. If the appliances don't have flame failure you will be left with an “open end”.

But the problem occurs with the fact that you no longer have any gas pressure between the gas valve and outlets.

It is stated in IGEM UP1a edition 2 that
Where a “safety shut off valve” has been automatically closed, before it can be re-opened, if there is any reasonable chance that the pressure has been lost on the downstream side, a tightness test should be performed before the valve is re-opened.

This would require either a visit from a Gas Safe engineer or a system capable of performing a down stream integrity check.

We feel it's far the better of the two options to have in place a combined gas pressure proving and ventilation interlock system from the beginning and recommend accordingly.

If you'd like to discuss this further please feel free to contact us on 0161 233 0600 or email at enquiries@medem.co.uk and we'll be more than happy to help.

If you require any additional information on our systems to help meet these design standards or wish to discuss the standards further please don't hesitate to contact us.
twitterlogo @MedemUkLtd

enquiries@medem.co.uk

British standard 6173:2009 relating to commercial kitchens

British standard 6173:2009 relating to commercial kitchens

Specification for the installation and maintenance of gas fired catering appliances for use in all types of catering establishments (2nd and 3rd family gases.

more >>

IGEM/UP/19 Edition 1, Design and application of interlock devices...

IGEM/UP/19 Edition 1, Design and application of interlock devices...

IGEM/UP/19 Edition 1, Design and application of interlock devices and associated systems used in with gas appliance installations in commercial catering establishments

more >>

Differential pressure proving?

Differential pressure proving?

Why choose Medem differential pressure proving?

The differential gas pressure proving method as developed and patented by Medem operates by *measuring* the pressure deferentially across the inlet and....

more >>

SEC-K - kitchen interlock

SEC-K - kitchen interlock

The SEC-K - kitchen interlock gas system. Ventilation interlock and gas proving system with multiple features available where and when required

more >>

VPS-K

VPS-K

Ventilation Interlock Only System System

VPS-K, a ventilation interlock system for use within commercial kitchens.

more >>

VGPS-evo - kitchen interlock gas system

VGPS-evo - kitchen interlock gas system

The VGPS-evo offers a complete single panel package patented by Medem UK

VGPS-evo, a gas pressure proving system with ventilation interlock and CO2 monitoring designed for commercial kitchens.....

more >>

SEC-K-NP- kitchen Interlock

SEC-K-NP- kitchen Interlock

The SEC-K-NP - kitchen interlock system.

Ventilation interlock panel with multiple features available where and when required including out of hours CO & CO2 monitoring to protect against the risk solid fuel cooking appliances.

more >>