SEC-B

SEC-B

The SEC-B, a multi-function solution designed for boiler rooms

  • Gas proving
  • Gas detection
  • Electrical isolation
  • Auto-restart after power failure
  • Auto-restart after a fire alarm reset

Gas detection
The SEC-B has been designed to accept a multiple of gas detectors including natural and LPG gases, carbon monoxide, Isolation of gas will occur upon detection of the target gases at prescribed levels.

Gas pressure proving
Using the patented differential pressure proving method the system checks the gas pipe work and appliances in a kitchen for gas leaks. It also monitors for low pressure and over pressure without opening the solenoid valve, making it the only truly safe method of proving available.

Auto-restart after power failure and fire alarm
The SEC-B can auto reset after an electricity supply failure or after a fire alarm has been manually reset when used in boiler room applications. This enables a building heating system to restart without manual intervention, minimising the chance of frozen pipes and a cold building.

If you require further information about this product please call us on 0161 233 0600 or email at enquiries@medem.co.uk and we'll be more than happy to help.

  • Sender
  • AD-MED-CO2 Sensor
  • SEC-B Main Panel

Design & Specification Documents

  • 5 Year Warranty

    5 Year Warranty

    Medem’s industry leading five-year warranty is a demonstration of the company’s confidence in the quality and design of our products.

    This applies to the main panels and sender units, gas detectors carry a two year warranty.

    Where we commission an installed system the warranty is extended from five to ten years. At the time of commissioning photos and gas pressure readings are recorded along with other relevent details of the installation. A 24 hour help line number and serial number is attached with the panel and all details are then entered on to the Medem database.

    5 & 10 year warrenty

  • Auto restart on power failure

    Auto restart on power failure

    As per HSE document PM5 and BS5885 when fitted within a boiler room you can enable our auto-restart option.

    When enabled, after a power cut the system will automatically preform a gas pressure test which will (assuming no gas leaks) re-establish the gas supply.

  • CO2 based ventilation control

    CO2 based ventilation control

    A 0 to 10 volt output on the panel can be connected to fan speed controllers in order to control the ventilation rates based on CO2 and temperature levels.
    This can help to save energy by controlling fans speeds so that as the occupancy rises and falls so will the ventilation rate.

  • Engineer Functions

    Engineer Functions

    Our systems include several engineer functions which allow a range of information to be displayed on screen.

    This not only aids in the original setup and commissioning but also enables us to provide a greater level of technical support on the telephone.

    Pressures

  • Fan interlocking

    Fan interlocking

    Fan interlocking is used where you require isolation of the gas supply when the ventilation is not running.

    In commercial kitchens it is a requirement to meet current regulations BS6173, BB100, UP11 (see our standards section for more information).

    Our recommended method of interlocking is “current monitoring” (see our model CM2M-K)

    CM2M-K

  • Fire Test Isolation Mode

    Fire Test Isolation Mode

    Fire Test isolation; In the event of a fire alarm test being undertaken the system can be set into a fire test isolation mode with three consecutive presses of the display detectors button (indicated) so ensuring the gas remains live during the test procedure.

    Once the test is completed the panel will revert to normal operation. If at any time you wish to cancel the operation of the fire test isolation repeat the three button presses on the panel and the panel will once again be connected to the fire panel.

    Note. In the event of an emergency requiring the isolation of the gas supply whilst the fire test isolation function is active the emergency stop button on the panel (and any others fitted) will still isolate the gas supply.

    Fire Test Mode

  • Over Pressure Alert

    Over Pressure Alert

    New to our systems is an over pressure alert

    Should the gas pressure rise above 70 mbar while gas is being used the panel will isolate the gas supply by closing the gas valve.
    When the panel is first switched on and if at that time the gas pressure is over 70 mbar then the gas valve will remain closed.
    Only a Medem gas pressure proving system measuring pressure on both sides of the valve can operate in the way described.
    70 mbar is above the pressure most appliances and other equipment (in buildings) has been designed to use, higher pressures can occur where a gas regulator fails.

The SEC Range adds more value with new features

The SEC Range adds more value with new features

The v3 update of the SEC Range offers the
best value on the market in the UK today.

more >>

IGEM/UP2/Edition 2

IGEM/UP2/Edition 2

Within IGEM/UP/2 Edition 2 it highlights the potential risks surronding the control of gas solenoid valves (AIV's) and automatic restarting.

more >>

Differential pressure proving?

Differential pressure proving?

Why choose Medem differential pressure proving?

The differential gas pressure proving method as developed and patented by Medem operates by *measuring* the pressure deferentially across the inlet and....

more >>

Building Bulletin 100, Design for fire safety in schools

Building Bulletin 100, Design for fire safety in schools

Building Bulletin 100, Design for safety in schools

This is a very comprehensive document so here are just a couple of extracts that ....

more >>